Summary/ Overview


The Cooper ULCF3000 is a high specification intelligent addressable, wall or rack mounted, UL Listed fire system available in various loop configurations. It combines sophisticated functionality with simple operation and aesthetically pleasing design.

Product Description/ Features/ Specifications


The control panel has the ability to support complex cause and effect programming and a wide range of user controllable functions make the system ideal for a diverse range of projects from industrial applications through to large multi site commercial developments.

The ULCF3000 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing.

Each of the system components have been specifically designed to operate as part of a ULCF3000 UL Listed system providing assurance that the panel, the detectors, the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device.

Features

  • Touchscreen Display
  • 2 or 4 Class A Style 7 SLC loops
  • Event History Buffer (9,999 events) with Date/Time stamp
  • 4 Notification appliance circuits (NAC's) outputs
  • 3 programmable general purpose relays
  • Dedicated alarm and trouble relays
  • Short circuit isolators incorporated into each loop
  • Up to 200 addresses per loop
  • Fully monitored network cable up to 126 panels
  • Optional integral printer
  • Alarm Verification
  • PAS (Positive Alarm Sequenc
  • Pre-Signal per Point (NFPA 70, 72 compliant)
  • Remote Alarm, NAC silenced, Alarm Reset, Trouble, Supervisory and drill via addressable module

Benefits

  • Supports a comprehensive range of soft addressing modules and devices for greater flexibility in design
  • Menu driven graphical user interface for ease of operation
  • Reduced commissioning time through soft addressing and auto learn functions
  • Programming and trouble-shooting time minimised by using a range of features such as auto config, walk test, system details, analogue values, etc

Code

ULCF3000 and ULCF3000RM

Description

UL Intelligent Addressable Control Panel

Standards

UL864 9th edition

Primary Operating Supply

120/240 V, 60 Hz, 2.0 A Supervised

Secondary Operating Supply

Battery Voltage
Battery Charge Current
Battery Derating Factor
Battery Capacity Supervised

24 V dc
1.0 A (max)
0.1
12 Ah (max)

Notification Appliance Circuits
Class B, Style Y, Sounder Group 1 sounder 1, Sounder Group 1 sounder 2, Sounder Group 2 sounder 1, Sounder Group 2 sounder 2

Output Voltage

24 V dc

Output Current

0.75 (max)

Line Impedance

50 ohms

 

When the product is powered by 240 V ac, the maximum current of 3.0 A is shared between these circuits.

 

When the product is powered by 120 V ac, the maximum current of 2.25 A is shared between these circuits.

 

Supervised, Power limited, Regulated

Notification Appliance Circuits
Class B, Style Y, SYNC MODULE.  NAC1, NAC2

Output Voltage

24 V dc

Output Current

0.5 A (max)

Line Impedance

50 ohms (max)

 

The maximum current of 0.5 A is shared between these circuits.

 

Supervised, Power limited, Regulated

Alarm, Trouble Contacts. Relay Expansion

Unity Power Factor

30 V dc

 

For connection to power limited sources only

Aux Relay (AC Trouble) Contacts

Unity Power Factor

30 V dc, 1 A

 

For connection to power limited sources only

Signaling Line Circuit Style [7] Class [A] – (Addressable Loop)

Rated Voltage

24 V dc

Maximum Current

500 mA

Line Impedance

50 Ω (max)

 

Supervised, Power limited

Network SLC

 

Voltage

5 V dc

Current

100 mA (max)

Line Impedance

50Ω (max)

 

Power Limited

 

Limited to same-enclosure Installations

Compatibility

Suitable for use with

Cooper UL fire systems

Proceed to Checkout Now →